Description of control options for REGULUS-system heaters
- SOLO, DUO, QUATTRO
- TRIOVENT, QUATTROVENT
- E-VENT, DECOR VENT
- DECOR PRO
- REVERS
- REGULLUS, SOLLARIUS, DUBEL, VERTAGO
REGULUS-system heater control – natural convection
VARIANT I = thermostatic valve + shut-off valve
STRAIGHT THERMOSTATIC VALVE ½’’
without setting, M30x1,5
Product code VAZTP15BN
STRAIGHT SHUT-OFF VALVE ½ “
Product code VAZOFPDN15
VARIANT II = VARIANT I + the following control elements
Distant-06C set – actuator mounted on the thermostatic valve connected by capillary (2 m) to the head mounted outside the duct.
THERMOSTATIC HEAD DISTANT-06C
with remote sensor
Product code VAGD06
VARIANT III = VARIANT I + the following control elements
Siemens RTN81 unit – a servo-motor installed on the thermostatic valve and connected on the capillary with a head installed outside the trench
THERMOSTATIC HEAD SIEMENS RTN81
remote, 2 m
Product code SIRTN1
VARIANT IV = VARIANT I + the following control elements
Wireless digital ZigBee network temperature controller HTRP-RF(50) enables temperature control via CO10RF coordinating unit in offline mode or via Internet gateway in online mode (UGE600-sold separately), it can be configured to work with electronic head (TRV). When using the UGE600 internet gateway – controllable via the SALUS Smart Home app.
Features:
- built-in energy-saving TPI control algorithm
- three temperature levels
- additional functions: PARTY and HOLIDAY
- possibility to work in manual mode (permanently or temporarily)
- VP function – protects thermostatic valves against freezing
- memory backup in case of power failure
SALUS HTRP-RF(50)
ZigBee network temperature controller,
Dimensions: 85 x 85 x 25,
power supply: 2xAA.
Product code SA023
SALUS CO10RF
Zig-Bee network coordinator (Offline),
can handle a maximum of 30 regulators,
9 skirting boards and 90 heater heads.
Product code SA027
SALUS TRV10RFM
ZigBee wireless thermostatic head – M30x1.5,
power supply: 2xAA.
Product code SA024
VARIANT V = VARIANT I + the following control elements
A wireless set AURATON 200 TRA consists of an electronic head and a temperature regulator (backlit LCD display). It enables a precise and effective regulation of temperature in rooms (daily cycle). One regulator may cooperate with any number of TRA heads.
Features:
- extended vacation mode
- service switch
- calibration of temperature and time indications
- possibility of working in on/off or PWM mode
- suitable for installation on M30x1.5 radiator inserts
AURATON 200 TRA
set consisting of temperature regulator
and electronic head, power supply: 2xAAA.
Product code AURTRARIG
AURATON TRA HEAD
electronic head.
Product code AURTRAG
Radiators with fans. Control variants.
VARIANT I = thermostatic valve + shut-off valve
STRAIGHT THERMOSTATIC VALVE ½’’
without setting, M30x1,5
Product code VAZTP15BN
STRAIGHT SHUT-OFF VALVE ½ “
Product code VAZOFPDN15
VARIANT II = VARIANT I + the following control elements
Bimetallic thermostat RT200 controls the operation of the fans. LED lighting. Wiring must be used between the duct fan and the thermostat (electrical cable 4 x min. 0,75 mm²).
SALUS RT200
electronic temperature controller
Product code SA006
SALUS T30NC
Thermoelectric actuator 230V.
M30 x 1.5 (currentless closed).
Product code SA004
*OPTIONAL
VARIANT III = VARIANT I + the following control elements
The electronic thermostat FC600 enables local control of both trench and wall mounted heaters.
Wiring must be used between the trench fan and the thermostat (electrical cable minimum 7 x 0,5mm2). The ROGK-03/230 box installed in the trench allows for fan speed control.
Features:
- time schedule: 5+2, 7-day, daily
- memory for settings in case of power loss
- Touch panel and picture menu
- automatic or manual fan speed regulation
- Possibility to connect supply temperature sensor CT10X
- after expansion with internet gateway UGE600 remote control is possible
- possibility of connecting wireless OS600 window/door opening sensor
- SmartPlug SPE600 can be connected
ROGK-T-03/230 CONTROLLER
Up to a maximum of 3 fans.
Dimensions of the box: W. 88 mm, L. 147 mm, H. 57 mm.
Product code ROGK03230
SALUS T30NC
Thermoelectric actuator 230V.
M30 x 1.5 (currentless closed).
Product code SA004
SALUS FC600
fan coil thermostat, 3-speed.
Product code SA002
VARIANT IVa
CONTROL VARIANT SIEMENS RDF 600T = VARIANT I + the following control elements
SIEMENS RDF 600T – electronic thermostat for fan operation:
- three-stage control of fan operation (automatic gear selection as a function of temperature, possibility of manual operation);
- automatic control of the thermal actuator;
- weekly work schedule programming function;
- flush mounting, standard 60 mm diameter box;
- cooperates with remote control IRA 211.
Wiring: between RDF 600T thermostat and control SP01 (SP06) electrical cable 6 x min. 0.5 mm2 – between the fan and the control electrical cable 3 x min. 0,75 mm².
CONTROL SYSTEM SP01 60W
up to 8 fans
flush box
dimensions: h. 53 mm,
width. 109 mm, L. 132 mm
Product code AS01
CONTROL SYSTEM SP06 250W
up to 35 fans
flush box
dimensions: h. 74 mm,
width. 144 mm, L. 172 mm.
Product code AS06
SALUS T30NC
Thermoelectric actuator 230V.
M30 x 1.5 (currentless closed).
Product code SA004
SIEMENS RDF 600T THERMOSTAT
weekly, flush mounted
Product code SIRDF6
VARIANT IVb
CONTROL VARIANT SIEMENS RDG 100T = VARIANT I + the following control elements
SIEMENS RDG 100T – electronic thermostat for fan operation:
- three-stage control of fan operation (automatic gear selection as a function of temperature, possibility of manual operation);
- automatic control of the thermal actuator;
- weekly work schedule programming function;
- surface mounting, easy to read display (dimensions: 53×75 mm);
- cooperates with remote control IRA 211.
Wiring: between RDG 100T thermostat and control SP01 (SP06) electrical cable 6 x min. 0.5 mm2 – between the fan and the control electrical cable 3 x min. 0,75 mm²
CONTROL SYSTEM SP01 60W
up to 8 fans
flush box
dimensions: h. 53 mm,
width. 109 mm, L. 132 mm
Product code AS01
CONTROL SYSTEM SP06 250W
up to 35 fans
flush box
dimensions: h. 74 mm,
width. 144 mm, L. 172 mm.
Product code AS06
SALUS T30NC
Thermoelectric actuator 230V.
M30 x 1.5 (currentless closed).
Product code SA004
SIEMENS RDG 100T THERMOSTAT
Weekly, surface-mounted.
Product code SIRDG1
REMOTE CONTROL
SIEMENS IRA 211
remote control, works with SIEMENS thermostats
Product code SIRA2
Fan module EV060/230V
for the heater with the length 60 cm
Fan module EV080/230V
for the heater of the length 80 cm
Fan module EV100/230V
for the heater of length 100 cm
Fan module EV120/230V
for the heater of length 120 cm
Fan module EV140/230V
for the heater with the length 140 cm
Fan module EV160/230V
for the heater of the length 160 cm
Fan module EV180/230V
for the heater of length 180 cm
Fan module EV200/230V
for the heater of length 200 cm
VARIANT I
SALUS RT200 electronic temperature controller
LED lighting.
Thermostat RT 200
SALUS T30NC 230V
VARIANT II
SALUS CONTROL
The electronic thermostat FC600 enables local control of both trench heaters and wall mounted radiators.
Features:
- Touch panel and picture menu
- automatic or manual fan speed regulation
- Possibility to connect supply temperature sensor CT10X
- time schedule: 5+2, 7-day, daily
- after expansion with internet gateway UGE600 remote control is possible
- memory for settings in case of power loss
- possibility of connecting wireless OS600 window/door opening sensor
- SmartPlug SPE600 can be connected
Use wiring between the duct fan and the thermostat (minimum 0.5 mm²)
VARIANT III
SIEMENS CONTROL
Electronic thermostat that controls the operation of the fans.
Basic features:
- three-stage control of fan operation (automatic gear selection as a function of temperature, possibility of manual operation),
- automatic control of the thermal actuator,
- weekly work schedule programming function,
- flush mounted,
- installation in a standard 60mm electrical box
- compatible with remote control: IRA 211.
Wiring: between RDF 600T thermostat and control SP01 (SP06) electrical cable 6 x min. 0,5 mm2).
Electric cable 3 x min. between fan motor and control system. 0,5 mm2.
Thermoelectric actuator – T30NC 230V M30x1,5 – (currentless closed)
SALUS T30NC 230V
Control system 230V
Siemens IRA 211
“TWINS” WHITE – angle fitting left – with connection head
Spacing of connecting studs: 50 mm.
Product code: VATWBI
“TWINS” GOLD – angle fitting left – with connection head
Spacing of connecting studs: 50 mm.
Product code: VATWZL
“TWINS” SATINE – angle fitting left – with connection head
Spacing of connecting studs: 50 mm.
Product code: VATWSA
“TWINS” BLACK – angle fitting left – with connection head
Spacing of connecting studs: 50 mm.
Product code: VATWCZ
Heads – technical data:
range: 8°C-30°C (16°C-30°C)
max. ambient temp: 50°C
closing time: 24 min.
the effect of pressure difference: <0,2 K
hysteresis: 0.3 K
effect of the heating medium temperature: <0,5 K
The REGULUS®-system thermostatic head is a heater temperature regulator :
- modern, ergonomic shape
- allows to maintain the desired thermal comfort in the room, taking into account the heat gains from other sources, such as lighting or insolation
- due to its construction it is easy to keep clean, which makes it suitable for rooms with high sanitary requirements.
Features of REGULUS-system thermostatic head:
- reliable liquid sensor
- control knob with digital marking
- frost protection function 8°C
- body made of high-quality plastic
Fan module RV060/24V
for heaters with length 60cm
Fan module RV080/24V
for heaters with length 80cm
Fan module RV100/24V
for heaters with length 100cm
Fan module RV120/24V
for heaters with length 120cm
Fan module RV140/24V
for heaters with length 140cm
Fan module RV160/24V
for heaters with length 160cm
Fan module RV180/24V
for heaters with length 180cm
Fan module RV200/24V
for heaters with length 200cm
Siemens room controller RDG 160 T
The RDG room controllers are very versatile. Thanks to their large display and intuitive operation with a rotary knob and large buttons, they are very easy to use and their illuminated display also allows operation in the dark. The desired application can be selected via DIP switches before the unit is installed. The RDG controller uses a two-position P or PI algorithm to control the room temperature.
Typical applications:
- Control in cooled or heated ceilings equipped with electric heaters or radiators, or control of underfloor heating
- Applications for 2-stage heating or cooling
- Additional functions such as remote temperature measurement for circulating air control, operating mode switching for energy saving mode switching, floor temperature limiting, dew point monitoring, etc.
Regulus thermostatic head gs. 02 – white
liquid with fixing nut
M30 x 1,5, closing dimension: 11.5 mm
closing stroke up to 2.5 mm
Regulus thermostatic head gs. 02 – satin
liquid with fixing nut
M30 x 1,5, closing dimension: 11.5 mm
closing stroke up to 2.5 mm
Regulus thermostatic head gs. 02 – gold
liquid with fixing nut
M30 x 1,5, closing dimension: 11.5 mm
closing stroke up to 2.5 mm
Straight thermostatic valve
SFP-15-1N with adjustable position, ½” M30 x 1.5
Thermostatic angle valve
SFK-15-1N with adjustable position, ½” M30 x 1.5
Straight shut-off valve
FP-DN-15, ½’’
Angle shut-off valve
FK-DN-15, ½
Straight dual shut-off valve
¾ x ¾
Angle dual shut-off valve
¾ x ¾
AURATON CONTROL
A wireless set AURATON 200 TRA consists of an electronic head and a temperature regulator (backlit LCD display). It enables a precise and effective regulation of temperature in rooms (daily cycle). One regulator may cooperate with any number of TRA heads. The set includes also: straight thermostatic valve and straight shut-off valve.
Properties:
- extended holiday mode
- service switch
- calibration of temperature and time indications
- possibility of working in on/off or PWM mode
- suitable for installation on M30x1.5 heater inserts